Space: Defines whether the Space (Sp) character (hex 20) is included in the ASCII
output report as a delimiter between the X and Y coordinate values. This option is
available only in GTCO formats. Choices are: Include or Exclude.

Decimal: Defines whether the period character (hex 2E) is included in the ASCII
output report between the units and tenths digits. This option is available only in
Summagraphics formats. Choices are: Include or Exclude.

Return: Defines whether the Carriage Return (CR) character (hex 0D) is included in
the ASCII output report as a terminator. This option is available in GTCO and
Summagraphics formats. Choices are: Include or Exclude.

Line Feed: Defines whether the Line Feed (LF) character (hex 0A) is included in the
ASCII output report as a terminator. This option is available in GTCO, CalComp and
Summagraphics formats. Choices are: Include or Exclude.

Mode Options

Mode: Defines how output reports are sent from the digitizer. Choices are: Point,
Line, Continuous, Line Incremental or Continuous Incremental.

Rate: Determines how fast output reports will be transmitted from the digitizer.
Choices are: 12, 50 or 100 reports per second.

Resolution: The smallest reported value returned by the digitizer. Choices are:
1000 lpi, 2000 lpi, 4000 lpi, 40 lpmm, 100 lpmm and 150 lpmm.

See the Advanced Programming Information section for more details.

Using the Custom Configuration Menu

If the application does not have a SuperSet Menu code, or if a different configuration is
required, then use the Custom Configuration Menu card to configure Roll-Up II. The
Custom Configuration Menu replaces the 24 switches that were associated with older
GTCO CalComp by Turning Technologies digitizers.

Configurations set up can be stored in any of ten user-definable SuperSet locations (codes
90 through 99) for recall at a later time. This allows Roll-Up II to be easily switched between
applications.