GTCO Roll-Up II - Users Guide User Manual

Page 30

Advertising
background image

Roll-Up II 30

9. If GTCOTEST indicates that the digitizer is functioning properly, check your software

application setup and SuperSet code for accuracy. If you have any questions about
your results or need assistance running GTCOTEST, contact our Technical Support
Department.

Roll-Up II Technical Specifications


Technology


Electromagnetic

Resolution

Up to 2000 lpi (lines/inch) or 100 lpmm (lines/millimeter)

Lock Height

0.5 inch (12.7 mm)

Coordinate Origin

Selectable (Factory default: lower left corner)

Recommended Roll Diameter 8 inches (200 mm)
Operating Temperature

41° to 115° F (5° to 46° C)

Storage Temperature

-4° to 158° F (-20° to 70° C)

Humidity Range

0% to 100%, non-condensing

Operating Modes

Point, Line, Continuous, Line Incremental, Continuous
Incremental, Remote Request

Baud Rates

1200, 2400, 4800, 9600, 19200 and 38400

Cursor Switches

Elastomeric keypad, rated life over 1 million actuations

Emulations

GTCO T5A, CalComp 9100/9500, Summagraphics
Microgrid and ID Series

Power Supply

Output voltage +9VDC at 500mA, Center positive

Interface

RS-232C (See Figure 4)

Adapter

9- to 25-pin (See Figure 5)