4. Networking with the RheoVac 950: If all of the items above are completed successfully, the

UIC or LAN computer should be able to network with the RheoVac 950. To search for the
RheoVac 950 from the UIC or LAN computer:

Method 1
a. Open Network Neighborhood.
b. Each RheoVac instrument is identified by a unique Network ID. The ID is “R” plus the

first five digits of the serial number found on the unit. (RheoVac Model 950 devices
which have not been serviced by the factory since August, 2003 may use the serial
numbers or “RheoVac 950” as the Network ID).

c. Look for the Network ID of your RheoVac 950. If the expected Network ID (see previous

paragraph) does not show up in the list, then type in the appropriate Address line (either
“\\RHEOVAC 950” or “\\R” and the first five digits of the serial number) and click the Go
button. This may take several seconds and then a RHEOVAC folder will appear, which
is the hard drive of the RheoVac 950.

d. Open the RHEOVAC folder then open the DATA folder. The \\Network ID

\RHEOVAC\DATA folder contains all the stored data. Use copy/paste functions (copy -
Ctrl C; paste - Ctrl V) to save the data files to the UIC or LAN computer.

Method 2
a. Open My Computer
b. Type in the Address line: \\Network ID (Network ID is defined above) and click the Go

button. This may take several seconds and then a RHEOVAC folder will appear, which
is the hard drive of the RheoVac 950.

c. Open the RHEOVAC folder then open the DATA folder. The \\Network ID\

RHEOVAC\DATA folder contains all the stored data. Use copy/paste functions to save
the data files to the UIC or LAN computer.

B.3

WINDOWS NT OR WINDOWS 2000 OPERATING SYSTEM

1. Ethernet Cable:

a. UIC Connection: use CAT5 network crossover cable (supplied by Intek) to connect the

Ethernet port of the UIC to the Ethernet port on the RheoVac 950.

b. LAN Connection: use CAT5 straight high noise-immune Ethernet cable (not supplied)

with RJ45 plug to connect the Ethernet port of the LAN to the Ethernet port of the
RheoVac 950.

2. Workgroup Identification: Unless otherwise requested, the Workgroup identification for the

RheoVac 950 will be WORKGROUP. To check/set the workgroup name: Right click on the
My Computer icon on the UIC or LAN computer desktop. Select Properties from the menu
that appears. Select the Network Identification tab of the System Properties dialog box that
appears. Verify that Workgroup is WORKGROUP.

3. Check for Installed Network Components: Click the Start button, select Settings, select

Network and Dial-up Connections. Or, right click My Network Places and select
Properties. Highlight the Local Area Connection that represents the Ethernet adapter. Right
click on Local Area Connection and select Properties. Under “Components checked are
used by this connection:” look for Client for Microsoft Networks and NetBEUI Protocol.
If these components are not installed, one or more of the following installations may be