Reporting current or selected values, Reporting supported range of parameter values, Result code – Longshine LCS-8056C2 User Manual
Page 57
![background image](/manuals/698242/57/background.png)
Commands for Host-Processed Modems Reference Manual
100498E
Conexant
3-35
Reporting Current or Selected Values
Command: +MS?
Response: +MS:
<carrier>,<automode>,<min_tx_rate>,<max_tx_rate>,<min_rx_rate>,<max_rx_
rate>
Note: The current active settings are reported under control of the +MR parameter.
Example: +MS:
V90,1,75,33600,75,56000
For default values. This example allows maximum system flexibility to
determine optimal receive and transmit rates during operation.
Reporting Supported Range of Parameter Values
Command: +MS=?
Response: +MS: (<carrier> range),(<automode> range),(<min_tx_rate> range),
(<max_tx_rate> range),(<min_rx_rate> range), (<max_rx_rate> range)
Example: +MS:
(B103,B212,V21,V22,V22B,V23C,V32,V32B,V34,
V90),(0,1),(75-33600),(75-33600),(75-56000),(75-56000)
Result Code
OK
Valid subparameter string
ERROR Otherwise.