S6 - wait time for dial tone before blind dialing, S7 - wait time for carrier after dial, for silenc, S8 - pause time for dial delay – Longshine LCS-8056C2 User Manual

Page 99

Advertising
background image

Commands for Host-Processed Modems Reference Manual

100498E

Conexant

3-77

S6 - Wait Time for Dial Tone Before Blind Dialing, or After “W” Dial Modifier

S6 sets one of two possible parameters:

1. Sets the length of time, in seconds, that the modem will wait before starting to dial after

going off-hook when blind dialing.

2. If enabled by country options in the INF file, S6 sets the length of time, in seconds, that

the modem will wait for dial tone when encountering a “W” dial modifier before
returning NO DIAL TONE result code.

The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less than 2
seconds.

Range: 2-255

seconds

Default: 2

S7 - Wait Time For Carrier After Dial, For Silence, or For Dial Tone After “W” Dial
Modifier

S7 sets one of three possible parameters:

1. Sets the length of time, in seconds, that the modem will wait for carrier before hanging

up. The timer is started when the modem finishes dialing (originate), or after the billing
delay in answer mode. In originate mode, the timer is reset upon detection of answer tone
if allowed by country restrictions.

2. Sets the length of time, in seconds, that modem will wait for silence when encountering

the @ dial modifier before continuing with the next dial string parameter.

3. If enabled by country options in the INF file, S7 sets the length of time, in seconds, that

the modem will wait for dial tone when encountering a “W” dial modifier before
continuing with the next dial string parameter.

Range: 1-255

seconds

Default: 50

S8 - Pause Time For Dial Delay

S8 sets the time, in seconds, that the modem must pause when the “,” dial modifier is
encountered in the dial string.

Range: 0-255

seconds

Default: 2