Reporting current or selected values, Reporting supported range of parameter values – Longshine LCS-8056C2 User Manual
Page 72

Commands for Host-Processed Modems Reference Manual
3-50
Conexant
100498E
<v8cf>=
Set the V.8 CI signal call function to the hexadecimal octet value
X.
<v8b>=
Decimal number which enables/disables V.8bis negotiation.
0
Disable V.8bis negotiation. (Default.)
1
Enable DCE-controlled V.8bis negotiation.
2
Enable DTE-controlled V.8bis negotiation.
<cfrange>=
“<string of values>“. Applicable only for <v8a>=5 (not
supported).
< protrange >=
“<string of values>“. Applicable only for <v8a>=5 (not
supported).
Default values: 1,1,,1,"",""
The ATD and ATA commands behave as specified in §6.3.1/V.25ter and §6.3.5/V.25ter,
respectively, and +A8n indications are not generated by the modem.
Reporting Current or Selected Values
Command: +A8E?
Response: +A8E:
<v8o>,<v8a>,<v8cf>[,<v8b>][,<cfrange>][,<protrange>]
Example:
+A8E: 1,1,,1,"",""
For the defaults
Reporting Supported Range of Parameter Values
Command: +A8E=?
Response: +A8E: (<v8o> range),(<v8a> range), (maximum size of v8cf in octets), (<v8b>
range),(<cfrange> option bit
range),(<protrange> option bit range)
Example: +A8E:
(1,6),(1,5),(1),(0),(1,6),(1)