Can switchbox – TeeJet Legacy 6000 Manual User Manual
Page 68

Legacy 6000
98-05053 R2
63
Swath manager Boom 50% and 100% Settings
the swath or entire boom is activated and deactivated based on the percentage
of swath in an applied area by turning off the regulating valve or drive mechanism
- not the individual boom sections. Boom 50% and Boom 100% settings do not
recognize individual boom sections.
Boom 50% shuts off the entire boom when half of the swath enters an
•
applied area.
Boom 100% shuts off the boom when the entire boom enters an applied
•
area.
Figure 3-17: Boom 50% and Boom 100% Settings
CaN Switchbox
For automatic section control using a teeJet technologies’ CaN Boom Switch-
box, the system must also contain a Switch Function module (SFm). the following
switch settings (each switch has a light to indicate the switch is in the “oN” posi-
tion) are required in order for Swath manager to operate:
auto Boom engage/disengage Switch set to “engage”
•
master Switch oN
•
active boom switches oN
•
oFF/auto/gSo switch must be in “auto” or “gSo”
•
main
regulating
valve is
closed