Blue

STORAGE

The motor should be stored in a clean, dry and vibrations free environment. . If the motor is to

be stored for a long period of time, the machined surfaces protected with anti-rust coating

should be checked and "touched up" if necessary.

If the motor is fitted with anti-condensation heaters, these should be connected during the

storage period.

MOUNTING AND START UP

Electric data of the motor, valid for the rated power, can be found on the nameplate.
It is the responsibility of the user to ensure that the motor nameplate voltage and frequency are

the same as the mains supply.
Connection to the mains supply should only be executed by a recognised professional,

respecting local demands and regulations.

The user must ensure that the diameter of the cable is adequate for the voltage and current

involved. (See nameplate data of motor)

The connection of the wires must be done as described in the connection diagram that is

delivered with the motor. The connection diagram is usually located inside the cover of the

terminal box. If the motor does not have a terminal box, it is located on the housing or attached

to the cable.

The connection diagram is structured as follows: (see example)

The leads can be coloured or numbered. Each line represents one lead.

The given connection diagram is an example only.

The motor must be protected against overloads and short-circuits.

When installing the motor, always connect the earth, using the earthing screw in the terminal

box or on the motor frame. Always check local regulations and demands.

The manufacturer cannot be held responsible for damage due to incorrect installation or use.

Free circulation of fresh air for cooling the motor must be guaranteed

The maximum ambient temperature must not exceed the given value that is indicated on the

nameplate and in the motor certificate.

To guarantee the explosion proof protection, certified explosion proof cable glands with sealing

joints adapted to the cable diameters, must be used.

THE MOTOR WILL LOSE ITS EXPLOSION PROOF CHARACTERISTICS IF THE CABLE AND

GLANDS ARE NOT FITTED CORRECTLY!