Note:

DO NOT make hose connections until the hose routing and

lengths have been determined. Remove the condensate trap and
drain hoses from the furnace and secure the drain hoses to the
drain stubs on the trap with the hose clamps (position the clamps
as shown in

Figure 10).

Install the condensate trap/hose assem­

bly to the furnace casing. Hook one side of the "clamp ears" on the
drain stub through the hole in the casing and push the condensate
trap into position. Secure with the two screws. Reconnect the
drain hoses to the stubs on the vent fitting and the plastic transi­
tion and secure with the clamps.

Relocate the plastic cap and clamp from the vertical transition

drain stub to the horizontal transition drain stub on the conden­
sate drain trap. Secure the clamps tightly to prevent condensate
leakage. Do not change the cap and clamp on the vent drain stub.
Mount the condensate drain trap in a vertical position to the left
side of the furnace using the two screws and gasket that are pro­
vided. Note: The condensate trap will be located under the fur­
nace in a vertical position when the furnace is placed horizontally
on the leftside. If needed, remove the hole plugs from the furnace
side panel and relocate to the open set of holes in the opposite
side panel.

NOTE: All gaskets and seals must be in place for sealed combus­

tion applications.

Remove the 90° elbow and vent fitting from the combustion blow­

er by loosening the clamps on the vent fitting. Connect the 90° el­
bow to the combustion blower using the rubber coupling and
clamps. Note for proper alignment of the vent pipe through the fur­
nace, the 90° elbow must be installed with the "HORIZONTAL"
lettering on the 90° elbow facing out. Connect all" section of

2"

PVC pipe (field supplied) to the 90° elbow using the rubber cou­
pling and clammps. The PVC pipe will extend through the top pan­

el about 1^2 - Connectthe vent fitting to the end of the 11" section
of PVC pipe using the clamp.

NOTE: The 90° elbow is approved for use inside the furnace
ONLY.

NOTE: The vent fitting

MUST

be installed with the airflow marking

arrow pointed toward the vent pipe, with the drain stub at a 5° to

1 0

° downward slope.

Plug the upper drain stub on the vent fitting with the yellow plastic

cap.

Connectthe PVC vent extension pipeto the vent fitting.

This pipe

has a built-in channel to assist vent condensate disposal.

Align the arrow on the PVC pipe with the airflow marking arrow on
the vent fitting. See label on the PVC pipe for proper installation.
This pipe may only be shortened if an elbow is used to connect the