Sears 9MPD User Manual

Page 41

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

to indicate the reason the control went into soft lockout. When the

6

+ X code is flashing, the SV9541 will attempt a new ignition sequence

after a five minute delay period, ifthecallfor heat is still present. Reset of the thermostat will initiate a new ignition sequence immediately.

NOTE 2: Any combination of 5 'abnormal' events during a single call for heat will result in soft lockout. An 'abnormal' event is a Flame
Sense Failure During Run, Airflow Proving Circuit Open During Run, or Limit Circuit Open During Run. The flash code will indicate which

was the last 'abnormal' event that put the system into the soft lockout state based on the table above.

44001

1114

00

rjT]

Advertising
This manual is related to the following products: