Control Center Fuse

The 24V circuit contains a 5-amp, automotive-type fuse located
on fan timer board. (See

Figure 32)

Any electrical shorts of 24V

wiring during installation, service, or maintenance may cause
fuse to blow. If fuse replacement is required, use only a fuse of

identical size (5 amp.)

7. Ductwork and Filter

A

1A#ARI\III\IB

CARBON MONOXIDE POISONING HAZARD

Failure to properly seal duct can result in death, personal

injury and/or property damage.

Do NOT draw return air from inside a closet or utility

room. Return air duct MUST be sealed to furnace casing.

Installation

NOTE:

Design and install air distribution system to comply with

Air Conditioning Contractors of America manuals and/or NFPA
pamphlets 90A and 90B or other approved methods that conform
to local codes and good trade practices.

1. When furnace supply ducts carry air outside furnace area,

seal return air duct to furnace casing and terminate duct
outside furnace space .

2.

Install air conditioning cooling coil (evaporator) on outlet

side of furnace.

3.

For furnaces installed without a cooling coil it is recom­

mended that the outlet duct be provided with a removable
access panel. This panel should be accessible when the
furnace is installed so the exterior of the heat exchanger
can be viewed for inspections. The access panel

MUST

be

sealed to prevent leaks.

4.

If separate evaporator and blower units are used, install

good sealing dampers for air flow control. Chilled air going

through thefurnacecould causecondensation and shorten
the furnace life.

NOTE:

Dampers (field supplied) can be either automatic or

manual. Manually operated clampers

MUST

be equipped with a

means to prevent furnace or air conditioning operation unless
damper is in the full heat or cool position.

[W|

44001

1114