Gleaning and Oiling—(continued)

To Glean the Stitch-Forming Mechanism

of Machines 66K, 99K and 185K.

If

the

stitch-forming

mechanism

should

become clogged with lint and interfere with the

perfect

operation

of

the

machine,

remove

the

bobbin case, as described in the following in­

structions, and dislodge the lint accumulated in
the machine.

To Remove Bobbin Gase.

SINGER

L

int

B

rush

Raise needle and presser foot.
Draw slide plate to the left.

F

ig

. 54.

To Replace Bobbin Gase.

Replace bobbin

case with its fork

straddling bracket G, Fig. 55.

Twist case to. the left, then gently

press down and back until edge of
sewing

hook

engages

groove

under

rim of bobbin case.

Return

latch

F

to

its

original

position.

• Remove bobbin from case.

Lift edge of slide plate and draw

it to the right until it is dis­
engaged from spring E, Fig. 53.

• Lift and move latch F, Fig. 54, to

position shown.

• Grasp bobbin case as shown.

• Tilt case to the left to raise the

forked end above bracket G.

• Turn forked end toward you, then

lift out bobbin case.