Programmable scan acquisition mode – ADLINK PXI-2006 User Manual

Page 41

Advertising
background image

Operation Theory

31

This method is very suitable for applications that needs to process
A/D data in real time. Under this mode, the timing of the A/D con-
version is fully controlled under software. However, it is difficult to
control the A/D con-version rate.

Specifying Channel, Gain, and Polarity

In both the Software Polling and programmable scan acquisi-
tion mode, the channel, gain, and polarity for each channel can
be specified and selected. With this configuration, signal
sources must be connected to the right connector as the speci-
fied settings.

When the specified channels have been sampled from the first
to the last data, the settings applied to each channel would be
the same until next change.

Example:

Typically you can set the input configuration for different chan-
nels:

Ch1 with unipolar ±10V
Ch2 with bipolar ±2.5V
Ch3 with no signal input (disabled)
Ch4 with bipolar ±1.25V

Programmable scan acquisition mode

Scan Timing and Procedure

It's recommended that this mode be used if your applications
need a fixed and precise A/D sampling rate. You can accu-
rately program the period between conversions of individual
channels. There are at least 2 counters, which need to be
specified:

SI_counter (24 bit):Specify the Scan Interval =

SI_counter / TIMEBASE

PSC_counter (24 bit):Specify Post Scan Counts,

i.e. the total sample count after a trigger
event,

The acquisition timing and the meanings of the 2 counters are
illustrated in Figure 10. The SCAN_START signal is derived from
the SI_counter, which will lead to the A/D conversion signal gener-
ation. Note that the DAQ/PXI-20XX series is a simultaneous sam-