Trigger modes, The data in the data buffer are 2v, 4v, -4v, 0v) – ADLINK PXI-2006 User Manual

Page 55

Advertising
background image

Operation Theory

45

Figure 21 shows a typical D/A timing diagram. D/A updates its out-
put on each rising edge of DAWR. The meaning of the counters
above is dis-cussed more in the following sections.

Figure 4-14: Typical D/A timing of waveform generation (Assuming the data

in the data buffer are 2V, 4V, -4V, 0V)

Note:

The maximum D/A update rate is 1MHz. Therefore, the min-

imum setting of the UI_counter is 40 while using an internal

TIMEBASE(40MHz).

Trigger Modes

Post-Trigger Generation

Use post trigger when you want to perform DA waveform right
after a trigger event occurs. In this trigger mode DLY1_Counter is
not used and you don’t need to specify it. Figure 4-15 shows a sin-
gle waveform generated right after a trigger signal is detected. The
trigger signal could come from a software command, an analog
trigger or a digital trigger. Please refer to section 4.5 for detailed
information.