Teristic, Figure 4-31: analog trigger block diagram – ADLINK PXI-2006 User Manual

Page 68

Advertising
background image

58

Operation Theory

level for SRC1 is ±10V and the resolution is 78mV (please refer to
Table 4-6), while the trigger range of SRC2 is the full-scale range
of the selected channel input, and the resolution is the desired
range divided by 256. For example, if the channel input selected to
be the trigger source is set bipolar and ±5V range, the trigger volt-
age would be 4.96V when the trigger level code is set to 0xFF
while 0V when the code is set to 0x80.

Figure 4-31: Analog trigger block diagram

The trigger signal is generated when the analog trigger condition
is satis-fied. There are five analog trigger conditions in the DAQ/
PXI-20XX. The DAQ/PXI-20XX uses 2 threshold voltages,
Low_Threshold and High_Threshold to build the 5 different trigger
conditions. Users could configure the trigger conditions easily by
software.

Trigger Level digital setting Trigger voltage

0xFF

9.92V

0xFE

9.84V

---

---

0x81

0.08V

0x80

0

0x7F

-0.08V

---

---

0x01

-9.92V

Table 4-7: Analog trigger SRC1 (EXTATRIG) ideal transfer characteristic