Operation Theory

43

put by feeding a sinusoidal signal into the reference input. The
range of the external reference should be within ±10V. Table 4-5
and 4-6 illustrates the relationship between digital code and output
voltages.

The D/A conversion is initiated by a trigger source. Users must
decide how to trigger the D/A conversion. The data output will start
when a trigger condition is met. Before the start of D/A conversion,
D/A data is transferred from PC’s main memory to a buffering Data
FIFO.

There are two modes of the D/A conversion: Software Update and
Timed Waveform Generation are described, including timing, trig-
ger source con-trol, trigger modes and data transfer methods.
Either mode may be ap-plied to D/A channels independently. You
can software update DA CH0 while generate timed waveforms on
CH1 at the same time.

Software Update

This is the easiest way to generate D/A output. First, users should
specify the D/A output channels, set output polarity: unipolar or

Digital Code

Analog Output

111111111111

Vref * (2047/2048)

100000000001

Vref * (1/2048)

100000000000

0V

011111111111

-Vref * (1/2048)

000000000000

-Vref

Table 4-5: Bipolar output code table (Vref=10V if internal reference is

selected)

Digital Code

Analog Output

111111111111

Vref * (4095/4096)

100000000000 Vref * (2048/4096)
000000000001

Vref * (1/4096)

000000000000

0V

Table 4-6: Unipolar output code table (Vref=10V if internal reference is

selected)