M o n i t o r i n g c a p a b i l i t i e s i n t h e w e b i n t e r f a c e

1 9 6

Python Application ZigBee Socket Error Counts

This section includes error counters that are specific to ZigBee Sockets implemented

using a Python application. These values will help determine the quality of data that is

being sent or received. Refer to the Troubleshooting information in your User Guide for

further help.

Transmit I/O Errors

The total number of transmitted frames which could not be transmitted due to an I/
O error.

Transmit CCA Failures

The total number of transmitted frames which could not be transmitted due to a CCA
error.

Transmit ACK Failures

The total number of transmitted frames which could not be transmitted due to an
ACK error.

Not Joined Errors

The total number of transmitted frames which were attempted to be transmitted to
an unjoined node.

Self Addressed Errors

The total number of transmitted frames for which a node attempted to transmit to
itself.

No Address Errors

The total number of transmitted frames for which the destination address could not
be found.

No Route Errors

The total number of transmitted frames for which a router to the destination could
not be found.

Receive Frame Errors

The total number of frames where an error occurred on receive.

Received Bytes Dropped

The total number of bytes dropped due to an exhaustion of internal buffers.