HOW DO I…

Recover Lift from LOWER LIMIT SWITCH ACTIVATION


When the Lift is lowered beyond its lower limit or Service/Maintenance position, a small

trip lever activates a safety shut-off on the lower limit switch. It is located on the
between the control box and scissors. If the lift will not respond to any command

buttons and the LED on the remote and control box blinks seven times proceed with the

following:

1.

Remove the back cover of the remote control with a small Phillips-head
screwdriver. Now you have access to the EMERGENCY OVERRIDE button on

the circuit board.

2.

Hold in the EMERGENCY button, followed by the UP button. The lift will return
to its HOME position in the ceiling, allowing the lift to reset its memory.

3.

Put the cover back on the remote.

4.

Put the lift into MANUAL MODE (OVERRIDE + UP).

5.

Press the OVERRIDE and SET buttons at the same time. This allows you to set
a new SERVICE / MAINTENANCE position for the lift.

6.

Press and hold the DOWN button until the striker plate foot (on the upper

scissor arm) is ½ inch from tripping the lower safety switch when it reaches its
desired SERVICE/MAINTENANCE position (but not so low as to activate the

safety switch again!)

Lower Limit

Striker plate

Adjustment foot

Lower Limit Switch

1/2” gap