Display Devices Lifts up up 35 lbs User Manual

Page 9

Advertising
background image

IP025-001 V3

IBL Lift Series Installation

07/05

Thor/Sales Info/Installation Materials/IBL Lift

9

PHYSICAL INSTALLATION

SIDE-MOUNTING

Side-mounting is typically used when installing the IBL-1522 lift between 16” on-center

floor joists.

NOTE for Retrofit installations with the IBL-1522:
Cut hole opening – 21”l x 14.5”w.


1.)

Determine the top height of lift/enclosure and mark the top position on the

joists. Mark the front and rear position of the lift on the joists – both the left and

right sides.

2.)

For installations which need the plenum enclosure, attach the plenum enclosure
to the 8 studs on the lift’s upper frame. Add flat washer, split lock washer and

7/16” nuts – tighten. Retrofit installations in sheetrock ceilings often require the

plenum enclosure to be removed.

3.)

Determine the best location for power, control and signal cables to enter the lift
enclosure. Use a knockout tool or drill holes in the enclosure for cables. We

recommend using flex conduit to the enclosure.


4.)

Install the four mounting brackets to the floor joists using ¼” x 1 ¼” lag screws

and washers. The brackets mount to the joist.


6.)

Raise the lift into position between the mounting brackets. Attach lift to

mounting brackets reinstalling the ¼”x 20 bolts. Do not tighten yet.

NOTE for Retrofit installations: Raise the lift on an angle – get one end of the lift

above the sheetrock, then lift the opposite end up above the ceiling. Level and attach
mounting brackets reinstalling the ¼”x 20 bolts. Do not tighten yet.

Mounting Bracket

Mounting Bracket bolts

Advertising