EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual
Page 130

Smart Mode
116
IQS-8100 Series Transport Blazer
Using SmartMode for Alarm/Error Monitoring
Range indicates the minimum and maximum optical power
values necessary to meet the standard BER for the test interface.
Power indicates the power level of the input signal in dBm. The
background color of the Power field indicates the input presence
as follow:
Frequency (bps) indicates the received signal frequency in bps.
Note: The port statistics are only refreshed (live) when the alarm scan is running.
3. To see the Section/RS/Line/RS/MS analysis, press the signal button and
press the Section/Line/RS/MS tab.
Background
color
Description
Green
Power level in-range.
Yellow
Power level out of operational range.
Red
Power level crosses the “Close-to-damage”
threshold.
Grey
LOS or invalid operational range value reported by
the optical device (SFP/XFP).