Alarm analysis, Frequency analysis – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual
Page 530
Advertising

Common Tabs
516
IQS-8100 Series Transport Blazer
Client Offset RX
Alarm Analysis
Frequency alarm indicates that the received client signal rate meets the
standard rate specifications (green) or not (red). Not available with
ODUflex CBR when Frequency Offset Analysis is disabled.
Frequency Analysis
The IQS-8100 Series allows the following frequency monitoring range.
Frequency (bps) indicates the frequency of the input signal in bps.
Client
Standard Rate Specification
Gb Ethernet
1250000000 ± 131875 bps (±105.5 ppm)
ODUflex CBR
Expected RX rate ±105.5 ppm
(See Expected Frequency (bps) on page 515)
Client
Measurement range
Gb Ethernet
1250000000 ± 150000 bps (±120 ppm)
ODUflex CBR
Expected RX rate ±120 ppm
(See Expected Frequency (bps) on page 515)