To create an Electrical SONET/SDH Test on an IQS-8105/15/20/30:
1. Test configuration:
1a. Select the source Clock Mode that will be used
for the test. Refer to Clock Configuration on
page 129 for more information.
1b. Select Normal as the Test Mode. Refer to Test
Configuration on page 126 for more
information.
1c. Select the Coupled check box to set the same
settings for both the TX and RX signals or clear the Coupled
check box to configure the TX and RX signal individually
(decoupled).
1d. Select the Through check box to loop the RX signal to the TX port.
The Clock Mode is automatically set to Recovered when the
Through check box is selected.
1e. Leave the SONET/SDH Intrusive and OTN Intrusive check boxes
cleared.
1f. Press Next.