Glossary

SONET/SDH Application

667

Next-Gen - Virtual Concatenation (VCAT)

³

High-Order Path Sequence Indicator

In addition to the MFI, the H4 byte also carries the sequence indicator
information. The sequence indicators are assigned by the source node
(PTE) and interpreted by destination node (PTE). The sequence
indicator (SQ) identifies the order in which the STS-1/STS-3c of a
SONET STS-1/STS-3c-Xv is assembled to create the contiguous
container (STS-1/STS-3c-Xc), as demonstrated in figure below.
Similarly, SQs are used to identify the order of VC-3/VC-4s used to
create the VC-3/4-Xc in SDH.

Sequence Indicator in High-Order Path VCAT Multiframe

The eight-bit SQ, supporting a range from 0 to 255, is formed by using
the H4 bytes (bits 1 to 4 of frame 14 and 15) in the first multiframe stage
(MFI1), as shown in figure H4 High-Order Path Multiframe Structure on
page 666. Eac
h VCG member is assigned an SQ. Normally, the first
timeslot associated to a VCG, composed of STS-1/3c-Xv or VC-3/4-Xv, is