Default button – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual
Page 457

Next-Generation Tabs
SONET/SDH Application
443
GFP OH TX
³
Extension Header
Note: CID and Spare are only available when EXI from GFP Frame TX on
page 432 is set to Linear.
³
CID (Channel IDentifier) allows to overwrite the communication
channel used for the signal transmission set from GFP Channel TX
on page 435. Choices are from 00000000 through 11111111 (0 to
255). The default setting is 00000000.
³
Spare allows to set the extension header Spare field. Choices are
from 00000000 through 11111111 (0 to 255).
Default Button
Click on Default to return to default configuration defined in the test case
for the selected GFP frame type (Frame Type Selection). The Default button
is only available when at least one overwrite is active.
0001 0010 Framed DVD-ASI
Reserved for future use
0001 0011 Framed 64B/66B Ethernet
0001 0100 Framed 64B/66B Ethernet Ordered Set
0001 0101
through
1110 1111
Reserved for future standardization
1111 0000
through
1111 1110
Reserved for proprietary use
UPI
Description for PTI = 000
Description for PTI = 100