Pattern configuration – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 459

Advertising
background image

Next-Generation Tabs

SONET/SDH Application

445

GFP Client TX

Pattern Configuration

Note: Pattern Configuration is only available when Pattern has been selected

during test setup.

Note: The internal PRBS Generator does not support a full Ethernet frame (no

Source Address and Destination Address are configurable) but it allows the
creation of a basic frame of configurable size with a fixed pattern that
offers the capability to fill the maximum payload value supported by a GFP
frame.

PRBS Payload Information Size (Bytes): Allows the selection of the size
of the data structure (payload information size) that carries the PRBS.

The default setting is 1500 bytes.

Note: The PRBS 2^31-1 pattern will be used. Refer to Pattern TX on page 405 for

more information.

Choices

For

1 through 65523 bytes

Linear Extension with pFCS

1 through 65527 bytes

Linear Extension without pFCS, or
Null Extension with pFCS

1 through 65531 bytes

Null Extension without pFCS

Advertising