Row 3, Row 4 – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 207

Advertising
background image

OTN Tabs

SONET/SDH Application

193

ODU OH RX

Row 3

³

TCM3/TCM2/TCM1: See Row 2 on page 192 for more information.

³

PM: Displays the following Performance Monitoring overhead bytes.

The first PM byte (Column 10) contains the TTI multiframe byte.

The second SM byte (Column 11) contains the BIP-8 byte.

The third PM byte (Column 12) contains the following sub-fields.

³

EXP: Displays the two Experimental overhead bytes received.

Row 4

³

GCC1: Displays the two General Communication Channel-1 bytes.

³

GCC2: Displays the two General Communication Channel-2 bytes.

³

APS/PCC: Displays the Automatic Protection Switching / Protection
Communication Channel overhead bytes. The Automatic Protection
Switching / Protection Communication Channel overhead bytes are
defined in the ITU-T G.709 standard.

³

RES: Displays the six Reserved (RES) bytes received.

Sub-field

Bit

BEI

1-4

BDI

5

STAT

6-8