Alarm/status unassigned messages, Loopback commands – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 316

Advertising
background image

DSn Tabs

302

IQS-8100 Series Transport Blazer

DS3 FEAC RX

³

Unassigned: An unassigned message has been detected in the last
second. An Unassigned message is only detected when receiving at
least 10 consecutive occurrences of a specific unassigned codeword.
An Alarm/Status codeword is also reported since Unassigned is part
of the Alarm/Status group.

Alarm/Status Unassigned Messages

Displays the current and previously received Codeword messages.

Current: Indicates the last valid message, if any, received in the last second
of measurment.

Previous: Indicates the message, if any, that was received just before the
current measurement.

Loopback Commands

Current: Displays the valid message received in the last second of
measurement. A valid message is detected only when receiving 10
consecutive occurrences of a specific Loopback Command immediately
followed by 10 occurrences of a specific Channel Codeword. See DS3
FEAC TX on page 297 for more information.

Previous: Displays the last valid message received excluding the actual
Current message.

Advertising