Standard Horizontal Flue

9.6 Flue Length

The maximum permissable horizontal flue length is 5.6 metres

for Betacom 24c and 4.6 metres for Betacom 30c, this can be

achieved by use of the accessories, see diagram 9.12.

However should additional 90º or 2 x 45º elbows be used then

the length MUST be reduced by 1 metre.

The diagram 9.10 shows the length achievable by using the

kit A2043400.

When extension pipes are used the flue system must be

designed to have a continuous fall to the boiler of at least 2.5º

44mm/metre to allow condensate to run back into the boiler

and out via the condensate drain.

The flue can be installed from inside the building, when

access to the outside wall face is not practicable.

9 Standard Flue - Length, Preparation and Installation

Diagram 9.10

202.5

477.5mm

477.5mm

202.5

20mm

15533

14475