Diagram 10.2

Diagram 10.3

10 Electrical Connection

10.2 System Controls 24V

WARNING: UNDER NO CIRCUMSTANCES MUST

ANY MAINS VOLTAGE BE APPLIED TO ANY OF THE

TERMINALS ON THE 24V CONNECTION.

The 24V low voltage room thermostat terminal block is

located on the left side of the rear cover of the controls box.

To access the 24V low voltage room thermostat terminal block

remove the front panel secured with two screws, lift off the

two retaining lugs, see diagram 10.1.

Carefully pull forward and down the controls fascia, see

diagram 10.2.

On connection of a voltage free room thermostat to the boiler,

the factory fitted bridge across the room thermostat terminal

block must be removed, see diagram 10.3.