11 commissioning, 6 checking the gas rate – Glow-worm Betacom C User Manual

Page 41

Advertising
background image

41

Diagram 11.8

SECURING

SCREWS

SUPPLY PIPE

CONNECTION

14586

GAS

ISOLATION

VALVE

Diagram 11.7

15525

Gas rate

Natural gas in (m

3

/ h)

Appliance

Maximum net heat input in kW

nominal

Combustion Products

CO

2

(Vol -%)

CO (ppm)

Appliance

Natural gas

Propane

Natural gas

Propane

Max

Min

Max

Min

Betacom 24c 8,60 ± 5 3,85 ± 5 9,60 ± 5 4,40 ± 5

< 400

< 400

Betacom 30c 8,10 ± 5 2,90 ± 5 9,30 ± 5 3,35 ± 5

< 400

< 400

tolerance

tolerance

tolerance

tolerance

Betacom 24c

Betacom 30c

28,5

25,7

3,02

2,72

11.6 Checking the gas rate

The boiler is fitted with a fully modulating automatic gas valve. With all other gas appliances turned off

measure the gas rate at the gas meter. Check that the gas rate is as stated in the table below:

Checking the combustion products

While adjusting the burner pressure at maximum and minimum, combustion products can be checked

according to the table below:

11 Commissioning

Appliance

Combustion Products

CO

2

(Vol - %)

CO (ppm)

Natural gas

tolerance

Propane

tolerance

Natural gas

tolerance

Propane

tolerance

Max

Min

Max

Min

Betacom 24c

8.60 ± 0.5

3.85 ± 0.5

9.60 ± 0.5

4.40 ± 0.5

< 400

< 400

Betacom 30c

8.10 ± 0.5

2.90 ± 0.5

9.30 ± 0.5

3.35 ± 0.5

< 400

< 400

Advertising