11 Commissioning - Nat. Gas (G20) to LPG (G31) Conversion

11.10 LPG CONVERSION - all models

IMPORTANT: Gas conversion must be carried out by a

competent person approved at the time by the Health and

Safety Executive.

Isolate the boiler from both the Gas and Electricity supplies.

The burner must be removed from the boiler by removing,

the front panel, hermetic chamber cover and combustion

chamber cover. Remove the two securing screws, one on

each side of the burner, see diagram 11.13.

The old injector bar (manifold) must be removed.

The ignition electrode and flame (ionisation) electrode

cables must be removed by opening the control panel and

gaining access to the PCB. Disconnect the plugs of the

ignition and flame (ionisation) electrodes, see diagram

11.15.

Fit new injector bar (manifold), new sealing washer and

tighten, ensuring that the injector size is marked 0.75 mm for

LPG (both for Betacom 24c and Betacom 30c)

Fit burner and re-assemble.

The joint must be checked for Gas Tightness.

14555

Diagram 11.15

FLAME AND IGNITION

ELECTRODE LEADS

14566

Diagram 11.14

SENSING TUBE

GROMMET

BURNER

14557

Diagram 11.13

SECURING SCREW

LEFT HAND SIDE

OF BURNER

RIGHT HAND

SIDE OF BURNER

Remove the gasket of cables with the cables inside.

1 2 3 4 5 6 7 8

ON

DIP

1 2 3 4 5 6 7 8

ON

DIP

DIP SWITCH

OFF POSITION

DIP SWITCH

ON POSITION

1 2 3 4 5 6 7 8

ON

P7

P5

P2

P4

DIP

8 DIP SWITCHES IN

THE OFF POSITION

MAIN PCB

Diagram 11.16