Installation, 6 electrical connections – Glow-worm Clearly Hybrid - Back-up Module System User Manual

Page 14

Advertising
background image

0020096317_01 - 08/10 - Glow-worm

- 12 -

INSTALLATION

5.3

Heating circuit

5.3.1

Connection from the hydraulic module to

the heating circuit

i

Make the connection limiting the load losses to a

minimum (the circuit should be as short as possible,

avoid bends and narrow sections...).

6

5

7

1

3

4

2

Key

1 Heating circuit

2 Return heating tubing leading to the hydraulic module (not

included)

3 Return heating circuit ¼ turn shut-off valve leading to the

hydraulic module (not included)

4 Return heating circuit filter leading to the hydraulic module

(not supplied)

5 Return heating connection (Ø ¾") leading to the hydraulic

module

6 flow heating connection (Ø ¾") leading to the hydraulic

module

7 flow heating tubing leading to the hydraulic module (not

included)

• Connect a pipe (2) to the return connection (5) leading to the

hydraulic module.

• Connect a pipe (7) to the flow connection (6) leading away

from the hydraulic module.

• Connect the pipes (2) and (7) to the heating circuit.

6 electrical connections

e

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of

the appliance must be made only by a qualified

engineer.

The appliance must be connected directly to an accessible,

fixed, switched, electrical outlet.

The manufacturer declines any responsibility for damages to

persons or others caused by the incorrect installation of the

appliance earthing. This includes failure to comply with current

standards.

Electrical components have been tested to meet the equivalent

requirements of BSEN 7671 and the BEAB regulations.

Main board

20 mm max.

1

2

Key

1 electrical wires

2 Insulation

When you connect the electrical wires to a connector on the

electronic board:

• Maintain a maximum distance of 20 mm between the

connector and the outer insulation.

• If using single core wires are used ensure that they are

wrapped together in an insulating sheath.

6.1

Heat pump

The cables connecting the isolator and the heat pump must be:

- suitable for a fixed installation.

- weather resistant.

- equipped with wires adapted to appliance’s power rating.

• Connect the heat pump to an electrical panel via an

independent protection system (20A differential breaker with

at least 3 mm between each contact).

Additional protection may be required during installation to

ensure overvoltage category II.

6.1.1

Access to main board

B

A

2

1

Key

1 Handle

2 box

• Remove the box (2) by pulling it toward you using the handle

(1).