Installation – Glow-worm Clearly Hybrid - Back-up Module System User Manual

Page 22

Advertising
background image

0020096317_01 - 08/10 - Glow-worm

- 20 -

INSTALLATION

12.3 "Thermostat / sensor" menu

• Using the buttons

,

select

Rmstat/sensor on the screen.

• Press the button

to confirm.

12.4 Thermostat(s)

• Using the buttons

,

select

Roomstat(s) on the screen.

• Press the button

to confirm.

• Using the buttons

,

select the area controlled by the

room thermostat.

• Press the button

to confirm.

On the room thermostat:

• Press the button

for 7

seconds.

• Enter the professional access code

(96).

• Via the installer menu > select > RF

> pairing.

• Press the room thermostat button

.

The control unit and the room

thermostat display “Connection finished

" on the respective screen.

If the message "Connection failed" is

displayed, press the button

and

repeat the operation.

• Repeat these operations for each

room thermostat (the zone number

is displayed on the thermostat at the

end of pairing).

• Press the button

twice.

12.5 Outdoor sensor

• Using the buttons

, select

Outdoor sensor on the screen.

• Press the button

to confirm.

• Using the buttons

,

select

Connection on the screen.

• Press the button

to confirm.

• Press the button on the outdoor

sensor to connect.

ON

1

Key

1 Outdoor sensor button

i

Once the sensor is detected, the message

«Connection completed» is displayed.

If unsuccessful, the message "Connection failure" is

displayed.

Press the button

and repeat the operation.

• Press the button

.

i

The External T°C Correction allows you to correct

the temperature measured by the outdoor sensor

(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).