Introduction – Glow-worm Clearly Hybrid - Back-up Module System User Manual

Page 8

Advertising
background image

0020096317_01 - 08/10 - Glow-worm

- 6 -

INTRODUCTION

2.4

example of Installation – Diagram 10 (10.3) : Hybrid back-up with 3 low heating temperature

zones (30-40°C) or 3 high heating temperature zones (< 80°C)

13 Wireless outdoor sensor

14 ebUS boiler

15 Heat pump electrical supply + protection (This must have it's

own single isolation)

16 Non-return valve

17 Heat pump

18 Heat pump circuit filter (not supplied)

19 glycol PRV discharge

A Heating circuit return

B Heating circuit flow

C boiler circuit return

D Boiler circuit flow

E Heat pump circuit flow

f Heat pump circuit return

g Heat pump circuit safety valve discharge

Key

1 Overheating safety (if underfloor heating)

2 Heating circuit "zone 1" (UFH shown, but can be underfloor or

radiators)

3 Climapro2 Rf programmable wireless room thermostat "zone 1"

4 2 port valve "heating zone 1"

5 Hydraulic module

6 2 port valve "heating zone 2"

7 Heating circuit "zone 2" (UFH shown, but can be underfloor or

radiators

8 Climapro2 Rf programmable wireless room thermostat "zone 2"

9 Climapro2 Rf programmable wireless room thermostat "zone 3"

10 Heating circuit "zone 3" (UFH shown, but can be underfloor or

radiators

11 2 port valve "heating zone 3"

12 Systempro control unit

i

Refer to the chapters “Hydraulic connection” and

“Electrical Connection” to connect the system.

b

This diagram shows the case of an installation with a

dual zone low temperature heating floor

(= outlet temperature < 40°C).

Zones must be same temperatures.

EBUS

E

F

G

B

A

C

D

230V

2

1

3

5

6

4

7

14

13

15

19

18

17

8

9

11

12

10

16