INSTALLATION

12.8.3

Heating circuit adjustment

2

3

1

4

Key

1 Speed control

2 Speed II (factory setting)

3 Speed I

4 by-pass screw

• Turn the control (1) to select pump speed I or I, in

accordance with the flow / pressure curve below.

• Depending on the design of the system the by-pass may

need further adjustment. It is adjusted clockwise to close and

anti-clockwise to open. This should be balanced to ensure

that it operates if the pump output is adjusted.

Hydraulic module pump flow / pressure curve

60
50

40
30

20

10

0

200

400

1000

800

600

1200 1400

B

2

1

4

3

Key

1 Speed 2, bypass closed

2 Speed 2, bypass opened

3 Speed 1, bypass closed

4 Speed 1, bypass opened

A Available pressure (kPa)

b flow within the circuit (l/h)

12.8.4

Venting the HP circuit

The venting of the HP circuit allows you to purge any air in the

HP circuit.

Ø14

A

B

1

3

4

1

2

Key

1 Air trap

2 Ø 14 mm flat wrench (*)

3 Hose

4 Container (*)

(*) Not included

• Connect one end of the hose (3) to the trap (1).

• Insert the other end of the hose (3) into the container (4) in

order to recover any residual glycol during the venting of the

circuit.

• Using the buttons

,

select

Vent HP circuit on the screen.

• Press the button

to confirm.

• Confirm with the button

in

order to begin the venting process.

You can start the heating circuit bleed at

the same time.