12.11 Heating system test

• Ensure that there is a heating demand to the control unit.

In the case of a multi-zone configuration, perform the test

zone by zone and ensure that the appropriate zone gets

warmer.

• Ensure that all the heating circuit’s thermostatic valves are

open.

• Balance the heat emitters, if necessary.

12.12 finishing

12.12.1 Radio signal test

• Put the room thermostats in place and ensure that the quality

of their radio signal is optimal.

i

Wait about fifteen minutes after commissioning

the thermostat(s) and the outdoor sensor before

performing the test.

• Hold down the room thermostat button

for 7 seconds.

• Enter the installer code "96" and confirm with the button

.

• Select on the screen > radio > test using the buttons

and confirm with the button

.

The room thermostat will show the signal quality for the room

thermostat and the outside sensor.

Signal quality

Comments

Excellent

Normal operation

Good
Low

Operational limit

None

Will not operate

• If the signal quality is none or bad, check that:

- the room thermostat batteries are properly installed in their

compartment,

- the polarity of the batteries is not reversed,

- the batteries are not exhausted. If so, replace them with

fresh batteries.

i

If the signal quality does not improve, move the

thermostat to limit distances and obstacles.

• Repeat these operations for each room thermostat.

12.12.2 Reinitialisation of fault log

• Reset the fault reports of all system appliances (see chapter

"Activation of control unit > Component Info").

• Press the control unit button

for more than 3 seconds

to display the main screen.

12.12.3 Description of the main screen

This screen indicates:

- the overall system efficiency,

- the current date,

- the time.

The date and time settings are configured via the room

thermostat.

• Consult the room thermostat instructions in order to adjust

settings.

12.12.4 System Performance Display

The performance indicator is based on the effectiveness of the

appliances during the past 24 hours.

Comment
Excellent
Good
OK
Standard

12.12.5 Status of appliances and system

The status of each of the installation’s components is checked

continuously. The result is displayed automatically every minute.

• Press the button

to

immediately obtain the status of the

installation.

After checking the installation, the

control unit displays the result for each

component and for the heating system

pressure.

The result can be:

- OK,

- NOT OK,

- _ _ (component not connected).

If the control unit displays "OK" for all appliances, no particular

action is required.

• If the control unit indicates <FAULT>, press the button

.

• If the control unit shows "_ _", check that the appliances are

switched on and connected to the control unit.

• Follow the indications on the control unit screen and consult

the "Troubleshooting" chapter for the corresponding failure

code.