3. Remove screws that attach fireplace floor as-

sembly to fireplace. Open lower louver door.

Carefully lift up fireplace floor assembly and

remove from fireplace, taking care to pull

flexible gas line through the access holes (see

Figure 6). Note: Be careful of all wires on

underside of log base.

CAUTION: Do not pick up

fireplace floor assembly by burn-

ers. This could damage burners.

Only handle base by grates.

INSTALLATION

Continued

Figure 6 - Removing Fireplace Floor

Assembly

Screws

Fireplace Floor
Assembly

Flexible Gas Line

ELECTRICAL CONNECTIONS FOR
POWER CORD

This fireplace operates on 120 VAC, 60 Hz

power. An electrical power cord is supplied with

this unit.
For Mantel Installation

1. Determine from which side of the fireplace the

power cord will exit. Locate the 1.5" diameter

hole near the center of floor support bracket on

appropriate side of lower cavity (see Figure 7).

2. Locate power cord. Remove wire tie or tape

holding plug end of power cord.

3. Power cord has 2 plastic hole bushings

threaded onto it. Route cord’s 3-prong plug

through the 1.5" diameter hole in appropriate

floor support bracket.

4. Push first plastic bushing completely through

hole. Squeeze bushing as needed to do this.

5. Install the second plastic bushing into the

hole in the floor support bracket by snapping

into place.

6. Route the 3-prong plug through the 1.5" hole

in fireplace outer casing.

7. Install the first plastic bushing into this hole

by snapping into place.

8. After you have connected to gas supply and

checked your gas connections (see pages 17

through 20), plug power cord into any conve-

nient 3-prong grounded wall receptacle near

fireplace.

For Recessed Installation

If an outlet is not installed in fireplace, install

model GA3555 - Outlet Kit with Cover. This

kit will supply a convenient 3-prong grounded

electrical outlet for power. Refer to installation

manual provided with this optional accessory for

instructions on wiring. Note: A qualified installer

must make all electrical connections.

RELOCATING WALL SWITCH
ASSEMBLY

Note:

The decorative wall switch plate supplied

is white. The wall switch plate may be painted to

match your decor.

The push-button switch and decorative wall

plate assembly supplied with your fireplace is

pre-mounted at the factory in the lower cavity of

the fireplace. You may relocate this wall switch

assembly to a more convenient location such as the

side of your mantel or directly onto the wall near

the fireplace. To mount the wall switch assembly,

you must first cut openings in the mantel or wall

where the switch will be located.

Figure 7 - Routing Power Cord

Power
Cord

Bushings

Hole in Floor
Support Bracket

Hole in Outer
Casing