8. Route electrical cord(s) through access holes

in either side of fireplace with bushing. Plug

electrical cord(s) into electrical outlet.

9. Check all gas connections for leaks. See

Checking Gas Connections, page 19.

10. Break off nailing flanges (see Figure 32)

with hammer or pliers if applicable and place

fireplace inside mantel opening. See mantel

instruction sheet for specific installation in-

structions. Be careful not to scratch or damage

hearth base or cabinet mantel.

INSTALLATION

Continued

Figure 31 - Installing Cabinet Mantel

Cabinet
Mantel

Figure 32 - Location of Nailing Flanges

Nailing
Flanges

11. Place metal trim on shoulder screws located

on the side and top of the fireplace (see Assem-

bling Perimeter Trim). Firmly snap trim over

shoulder screws. Align fireplace in mantel

assembly so the trim overlaps mantel evenly

on all three sides.

12. Lower bottom louver door. Use 3" wood screws

provided with mantel accessory to attach fire-

place to base (see mantel instruction sheet).

13. Check all gas connections for leaks. See

Checking Gas Connections, page 19.

Figure 33 - Inserting Fireplace Into

Cabinet Mantel

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves

installing fireplace into a framed-in enclosure.

This makes the front of fireplace flush with wall.

If installing a mantel above the fireplace, you must

follow the clearances shown in Figure 37, page

23. Follow the instructions below to install the

fireplace in this manner.

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

1

3

/

4

"

1. Frame in rough opening. Use dimensions

shown in Figure 34, page 22 for the rough

opening. If installing in a corner, use dimen-

sions shown in Figure 35, page 22 for the

rough opening. The height is 33" which is the

same as the wall opening above.

2. Install and properly ground GA3555, three-

prong 120 volt electrical outlet, in fireplace.

Follow instructions included in kit (see Ac-

cessories, page 40).