INSTALLING THERMOSTATIC
BLOWER ACCESSORY

NOTICE: Shut off gas supply and

disconnect heater from gas supply

if installing blower in previously

installed fireplace. Contact a quali-

fied service person to do this.

1. If fireplace screen and floor are still installed,

see Removing Fireplace Screen and Floor

Assembly, page 9.

2. Using screw provided, attach green ground

wire from speed control cord to blower hous-

ing. Tighten screw securely (see Figure 18).

3. Place the blower against lower rear wall of

firebox outer wrapper with the exhaust port

directed upward. Align the holes in top mount-

ing tabs of blower with holes in wall of wrapper

(see Figure 19). Using two #8 screws provided,

mount blower and tighten screws firmly.

4. Remove the three screws (do not discard) and

cover plate from center of firebox wrapper rear

wall. Discard this cover plate (see Figure 18).

5. Mount the supplied thermostatic switch and

cover assembly into firebox wrapper wall. Do

this by feeding terminal ends of wire harness

into the hole. Allow wires to fall to bottom of

firebox cavity (see Figure 18).

6. Using three screws from step 7, attach switch

and cover assembly to firebox wrapper rear

wall. Tighten screws firmly (see Figure 18).

INSTALLATION

Continued

Figure 18 - Installing Switch and Cover

Assembly and Speed Control

Thermostatic Switch
and Cover Assembly

Red
Wire

Blue
Wire
Black
Wire

Green Wire

Speed Control

White
Wire

7. Firmly attach red wire from the thermostatic

switch and cover assembly to either of the ter-

minals on the blower motor (see Figure 18).

8. Firmly attach black wire from speed control

cord to blue wire from thermostatic switch

and cover assembly (see Figure 18).

9. Firmly attach white wire from speed control

cord to remaining terminal on blower motor

(see Figure 18).

10. Place control knob provided on plastic control

shaft of speed control (see Figure 20).

11. Mount the speed control onto the front leg of

the left floor support bracket using 2 screws

provided (see Figure 20).

WARNING: Failure to connect

all wires properly as indicated

may cause electrical short circuit

or personal injury. A qualified

electrician should check that all

connections are made properly.

Blower

#8 Screws

Figure 19 - Mounting Blower to Firebox

Lower Rear
Wall of
Firebox

Exhaust
Port

Top
Mounting
Tab

Control
Knob

Screws

Speed
Control

Floor
Support
Bracket

Figure 20 - Attaching Speed Control