OBSERVED PROBLEM

Slight smoke or odor during initial

operation

Moisture/condensation noticed

on windows

Heater produces a whistling noise

when burner is lit

When ignitor button is pressed,

there is no spark at ODS/pilot

(manual ignition mode)

When ignitor button is pressed,

there is spark at ODS/pilot but no

ignition (manual ignition mode)

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

3. Residues from manufacturing

processes and logs curing

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable

5. Bad piezo ignitor

6. Ignitor electrode broken

7. Ignitor electrode positioned

wrong

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not in PILOT

position

3. Air in gas lines when in-

stalled

4. Depleted gas supply (pro-

pane/LP only)

5. ODS/pilot is clogged

6. Gas regulator setting is not

correct

REMEDY

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 29)

2. Replace regulator

3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation requirements

(page 6)

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installation

clearances (see page 9)

4. Clean burner (see Cleaning

and Maintenance, page 29) or

replace burner orifice

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

3. Tighten nut holding piezo ignitor

to base panel of log set. Nut is

located behind base panel

4. Replace ignitor cable

5. Replace piezo ignitor

6. Replace pilot assembly

7. Replace pilot assembly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position full counterclockwise

3. Continue holding control knob

in full counterclockwise posi-

tion. Repeat igniting operation

until air is removed

4. Contact local propane/LP gas

company

5. Clean ODS/pilot (see Cleaning

and Maintenance, page 29) or

replace ODS/pilot assembly

6. Replace gas regulator