Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors. Cleaning supplies,

paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These

fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

ODS/pilot lights but flame goes

out when control knob is released

(manual ignition mode)

Fireplace produces a clicking/

ticking noise just after burners

are lit or shut off
Fireplace produces unwanted

odors

Fireplace shuts off in use (ODS

operates)

Gas odor even when wall switch

and remote control buttons and

switches are in OFF position

POSSIBLE CAUSE

1. Control knob not fully turned

counterclockwise

2. Control knob not held long

enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

OD S/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged

7. Control valve damaged
1. Metal expanding while heating

or contracting while cooling

1. Fireplace burning vapors

from paint, hair spray, glues,

cleaners, chemicals, new car-

pet, etc. (see IMPORTANT

statement above)

2. Gas leak. See Warning

statement above

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak. See Warning

statement above

2. Control valve defective

REMEDY

1. Turn control knob fully coun-

terclockwise

2. After ODS/pilot lights, hold

control knob for 30 seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 29) or replace ODS/pilot

assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly

7. Replace control valve
1. This is normal with most fire-

places. If noise is excessive,

contact qualified service person

1. Open window and ventilate

room. Stop using odor caus-

ing products while fireplace is

running

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 19)

1. Open window and/or door for

ventilation

2. Contact local gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 29)

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 19)

2. Replace control valve