8. Remove paper template from wall.

9. Drill 3/8" holes at each mark.

10. Using a straight edge and pencil, connect the

outer edges of the 4 holes for the rectangle (see

Figure 10). This will give you cutting lines for

the rectangle you will cut in the wall.

11. Using a keyhole saw, hack saw blade, drill,

file or other suitable tool, carefully cut out the

rectangular opening. Note: The corners of the

rectangle may be round. IMPORTANT: Do not

exceed the size of the rectangle on template.

12. From inside the recessed opening for the

fireplace, carefully pass wall switch assembly

through the rectangular opening to the outside

of the wall.

13. Using wall anchors supplied in hardware pack-

age, fold wall anchor as shown in Figure 11.

14. Insert wall anchor, wings first, into hole. Tap

anchor flush to wall.

15. For thin walls (1/2" or less), insert red key into

wall anchor. Push red key to “pop” open anchor

wings. See Figure 12. IMPORTANT: Do not

hammer key! For thick walls (over 1/2" thick),

do not pop open wings.

INSTALLATION

Continued

16. Position wall switch assembly vertically over

wall openings with decal lettering upright (see

Figure 13).

17. Insert mounting screws, removed in step

2 of Relocating Wall Switch Assembly on

page 10, through holes in wall plate and

into wall anchors.

18. Tighten screws until wall plate is firmly at-

tached to wall. Do not overtighten.

Figure 13 - Securing Wall Switch

Assembly

Screws

Wall Switch
Assembly

Opening in Wall
or Mantel Wall

Figure 11 - Folding

Anchor

Figure 12 - Popping

Open Anchor Wings

for Thin Walls

Figure 10 - Using Template for Wall

Switch Assembly Installation

Template
from This
Manual

Cutting
Lines

Make
Marks at
Centers
of Holes

Tape

Mounting Wall Switch Assembly to Side
of Mantel

7. Create three openings in the mantel wall ac-

cording to Template 2, page 41. This is best

done by making a pattern to work with on the

mantel. Carefully cut page 39/40 from manual

and tape paper template vertically onto mantel

wall at preferred location. Pierce the paper at

the centers of the 2 holes with a nail or sharp

pencil, leaving a mark on the wall. Do the

same at centers of the four circles near the

corners of the rectangle.

8. Remove paper template from mantel wall.

9. Drill 1/8" pilot holes at each mark for top and

bottom screw holes. Drill 3/8" holes at each

mark for centers of four circles near corners

of rectangle.

10. Using a straight edge and pencil, connect the

outer edges of the 4 holes for the rectangle (see

Figure 10). This will give you cutting lines for

the rectangle you will cut in the mantel wall.

11. Using a keyhole saw, hack saw blade, drill,

file or other suitable tool, carefully cut out the

rectangular opening. Note: The corners of the

rectangle may be round. IMPORTANT: Do not

exceed the size of the rectangle on template.

12. Carefully pass wall switch assembly through

rectangular opening from inside mantel (see

Figure 13).