Operating fireplace – Desa CGEFP33PRB User Manual

Page 26

Advertising
background image

www.desatech.com

111245-01C

26

D. Do not use this appliance if any part has been

under water. Immediately call a qualified

service technician to inspect the appliance and

to replace any part of the control system and

any gas control which has been under water.

NORMAL LIGHTING

INSTRUCTIONS

WARNING: You must oper-

ate this heater with the fireplace

screen in place. Make sure fire-

place screen is in place before

running heater.

NOTICE: During initial operation of

new heater, burning logs will give

off a paper-burning smell. Open

damper or window to vent smell.

This will only last a few hours.

1. STOP! Read the safety information on

page 25.

2. Make sure equipment shutoff valve is

fully open.

3. Wait five (5) minutes to clear out any gas.

Smell for gas around heater and near floor. If

you smell gas, STOP! Follow “B” on page 25.

If you don’t smell gas, go to the next step.

A. Using Supplied Wall Switch Assembly

1. Set manual ignition bypass switch on the

control panel to the OFF position (auto-

matic ignition position).

2. Press ON/OFF button. Hold for 6 seconds.

Gas valve will open and electronic ignition

will begin sparking to light pilot. LED will

light. Note: You may be running this heater

for the first time after connecting to gas sup-

ply or at the start of your heating season.

If so, the ON/OFF button may need to be

pressed again. This will allow air to bleed

from gas system. If several attempts to light

pilot fail, contact a qualified service person

or gas supplier for repairs. Until repairs

are made, light and operate manually (see

Manual Lighting Instructions for Electric

Power Outage, page 27).

OPERATING FIREPLACE

Continued

Figure 47 - Control Locations

Manual Ignition Bypass Switch
(Up is for Remote Control)

ON/OFF
Button

HI/LO
Button

Wall
Switch
Assembly

LED

Automatic
Ignitor
Electrode

Figure 48 - Pilot (Natural Gas)

Manual Ignitor
Electrode

Figure 49 - Pilot (Propane/LP Gas)

Automatic
Ignitor
Electrode

Pilot
Burner

Manual Ignitor
Electrode

Pilot
Burner

B. Using Hand-Held Wireless Remote
Control

1. Set manual ignition bypass switch on

control panel to OFF position (automatic

ignition position).

2. Wait five (5) minutes to clear out any gas.

Smell for gas around heater and near floor.

If you smell gas, STOP! Follow “B” on page

25, column 2. If you don’t smell gas, go to

the next step.

3. When pilot flame is lit, the thermocouple is

heated by the flame. When thermocouple

becomes hot (5 to 15 seconds), main burner

will automatically light on high flame.

4. To lower flame, push HI/LO button on wall

switch once. Note: This fireplace does not

have a pilot-only mode.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.