INSTALLATION

Continued

WARNING: Failure to connect

all wires properly as indicated

may cause electrical short circuit

or personal injury. A qualified

electrician should check that all

connections are made properly.

12. Plug in blower power cord.

a. If your firebox is installed as a free-

standing unit with an accessory mantel,

determine whether the power cord will

exit the left side or the right side of the

firebox. Install one plastic bushing provided

into the 1

1

/

2

" hole in the floor support on

the exit side. Install the second bushing

provided into the 1

1

/

2

" hole in the outer

casing through which the power cord will

exit (see Figures 21 and 22). Route power

cord through plastic bushings and plug the

power cord into a properly grounded three-

prong wall receptacle near the firebox.

b. If your fireplace system installation is

recessed and if an outlet is not installed in

your fireplace, you must install the GA3555

Outlet kit with cover in your fireplace which

will supply a convenient 3-prong grounded

electrical outlet for your blower. Refer to the

installation manual provided with the model

GA3555 accessory for instructions on wiring

the duplex outlet. Note: A qualified installer

must make all electrical connections.

13. Check to make sure that the power cord and all

wires are completely clear of the blower wheel

and that there are no other foreign objects in

blower wheel.

CAUTION: Never touch the

blower wheel while in operation.

14. Peel off backing paper and stick supplied

wiring diagram decal near center of firebox

bottom (see Figure 23).

15. If gas connections have been made and

checked, replace fireplace floor assembly in

fireplace. Feed flexible gas supply line into

fireplace base area while replacing fireplace

floor assembly. Make sure the entire flexible gas

line is in fireplace base area. IMPORTANT: Do

not pick up fireplace floor assembly by burners.

This could damage burners. Only handle base

by grates. Note: Be careful of all wires and

components on underside of floor assembly.

Figure 21 - Installing Plastic Bushing for

Power Cord (Right Side Exit Shown)

Right Floor
Support
Bracket

Plastic
Bushing

Figure 22 - Installing Bushings

(Left Side Exit shown)

Bushing Location for
Recessed Installation

Bushing
Location for
Freestanding
Installation

Plastic
Bushing

Var

iab

le

Fan

Sw

itch

Wh

ite

Wh

ite

Blac

k

Gre

en

On

110

/11

5

V.A

.C.

Blowe

r

Moto

r

Blac

k

Blac

k
Blac

k

Off

Figure 23 - Location of Wiring Diagram

Decal 3" from Blower

Wiring
Diagram

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

Advertising