13. Position wall switch assembly vertically over

opening with decal lettering upright. Make

sure wires freely pass through wall without

binding. Align holes in wall plate with 1/8"

pilot holes in mantel wall.

14. Drive mounting screws, removed in step 2 of

Relocating Wall Switch Assembly on page 10,

through wall plate holes and into pilot holes

in mantel wall.

15. Tighten screws until wall switch assembly is

firmly attached to mantel. Do not overtighten.

INSTALLING VARIABLE SPEED
BLOWER ACCESSORY

NOTICE: Shut off gas supply and

disconnect heater from gas supply

if installing blower into previously

installed fireplace. Contact a quali-

fied service person to do this.

1. If fireplace screen and floor are still installed,

see Removing Fireplace Screen and Floor

Assembly, page 9.

2. Attach the power cord to the blower motor

by firmly pushing the two female terminals at

the end of the power cord onto the two spade

terminals on the blower motor.

3. Attach green ground wire from power cord

to blower housing using screw provided (see

Figure 14). Tighten screws securely.

4. Place the blower against lower rear wall of

firebox outer wrapper with the exhaust port

directed upward. Align the holes in top mount-

ing tabs of blower with holes in wall of wrap-

per (see Figure 14). Using 2 screws provided,

mount blower and tighten screws securely.

5. Be certain that all wire terminals are securely at-

tached to terminals on blower motor and that the

screw retaining the green ground wire is tight.

6. Place control knob provided on plastic control

shaft of speed control.

7. Mount the speed control on the front leg of

the left floor support bracket using 2 screws

provided (see Figure 15).

8. Plug in blower power cord.

a. If your fireplace system is installed as a

freestanding unit with an accessory man-

tel, determine whether the power cord will

exit the left side or the right side of the fire-

box. Install 1 plastic bushing provided into

the 1.5" hole in the floor support bracket

INSTALLATION

Continued

Figure 14 - Mounting Blower to Firebox

Lower Rear
Wall of Firebox

Blower

Top
Mounting
Tab

Exhaust
Port

Screw

Green Ground Wire

Screws

Figure 15 - Attaching Speed Control to

Firebox

Screws

Speed
Control

Control
Knob

Left Floor
Support Bracket

Control
Shaft

on the exit side (see Figure 16). Install the

second plastic bushing provided into the

1.5" hole in the outer casing through which

the power cord will exit. Route power cord

through both plastic bushings and plug

the power cord into a properly grounded

3-prong wall receptacle near the firebox.

b. If your fireplace system installation is

recessed and if an outlet is not installed

in your fireplace, you must install the

GA3555 Outlet kit with cover in your

fireplace which will supply a convenient

3-prong grounded electrical outlet for

your blower. Refer to the installation

manual provided with the model GA3555

accessory for instructions on wiring the

duplex outlet. Note: A qualified installer

must make all electrical connections.