Operating fireplace – Desa CGEFP33PRB User Manual

Page 27

Advertising
background image

www.desatech.com

111245-01C

2

3. Point remote control toward the lower

front of fireplace and push both buttons

at the same time. Hold for 6 seconds. The

gas valve will open and electronic igni-

tion will begin sparking to light the pilot.

Note:

You will be able to hear a clicking

sound during this process. LED on wall

switch will light.

Note: You may be running this heater for

the first time after connecting to gas supply

or at the start of your heating season. If

so, the ON button may need to be pressed

again. This will allow air to bleed from gas

system. If several attempts to light pilot fail,

contact a qualified service person or gas

supplier for repairs. Until repairs are made,

light and operate manually (see Manual

Lighting Instructions for Electrical Power

Outage).

4. When pilot flame is lit, the thermocouple is

heated by the flame. When thermocouple

becomes hot (5 to 15 seconds), main burner

will automatically light on high flame.

5. To lower flame, point remote control toward

lower front of fireplace and push HI/LO

button once.

Note: This fireplace does not have a pilot-

only mode.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote
Control

Point remote control toward lower front of fire-

place and push both buttons at the same time.

MANUAL LIGHTING

INSTRUCTIONS FOR

ELECTRICAL POWER

OUTAGE

WARNING: You must oper-

ate this heater with the fireplace

screen in place. Make sure fire-

place screen is in place before

running heater.

OPERATING FIREPLACE

Continued

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Open damper or window to vent

smell. This will only last a few

hours.

Because this fireplace has an electronic ignition

system, in the event there is a loss of power, it

will be necessary to manually light the pilot with

the piezo ignitor. After the pilot is lit, the main

burner will light automatically.

1. Follow steps 1 through 3 under Normal

Lighting Instructions, page 26.

2. Set manual ignition bypass switch on con-

trol panel to ON position (manual ignition

position). See Figure 50.

3. The pilot is attached to the rear of the front

burner. You will be able to see the pilot

and spark electrode without removing the

screen or logs.

4. Place the magnetic manual override handle,

provided with this unit, on the end of the

gas valve stem (see Figure 50).

5. Turn the override handle fully counter-

clockwise

to the PILOT position.

The handle will not stop but will begin

to slip when you have fully turned to the

PILOT position.

6. While holding the valve handle in the

PILOT position, press and release piezo

ignitor button (see Figure 50). This will light

the pilot. If needed, keep pressing ignitor

button until pilot lights.

Figure 50 - Control Locations

Manual Ignition
Bypass Switch
(Down is ON)

Magnetic
Manual
Override
Handle

ON/OFF
Button

HI/LO
Button

Piezo Ignitor

Wall
Switch

Gas
Valve

LED

LED

Advertising