Product identification, Safety information – Desa CGEFP33PRB User Manual

Page 4

Advertising
background image

www.desatech.com

111245-01C

4

SAFETy INFORMATION

Continued

PRODUCT

IDENTIFICATION

Log Set

Wall Switch
Assembly

Piezo
Ignitor

Remote
Control

Manual
Override
Handle

Manual Ignition
Bypass Switch

Figure 1 - Fireplace Floor Assembly

Figure 2 - Fireplace

Top Louver Assembly

Firebox
Hood

Bottom Louver
Assembly

Screen
Assembly

Top Outer
Casing

Firebox
Support

Blower Assembly
(Optional)

4. This fireplace shall not be installed in a bed-

room or bathroom.

5. Do not use this fireplace as a wood-burning

fireplace. Use only the logs provided with the

fireplace.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. To prevent the creation of soot, follow the instruc-

tions in Cleaning and Maintenance, page 29.

8. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If

heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

9. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS shuts down the fireplace if not enough

fresh air is available. See Air for Combustion

and Ventilation, page 6. If fireplace keeps

shutting off, see Troubleshooting, page 30.

10. Do not run fireplace

• where flammable liquids or vapors are used

or stored

• under dusty conditions

11. Do not use this fireplace to cook food or burn

paper or other objects.

12. Do not use fireplace if any part has been exposed

to or under water. Immediately call a qualified

service technician to inspect the fireplace and to

replace any part of the control system and any

gas control which has been under water.

13. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

14. Turn fireplace off and let cool before servicing.

Only a qualified service person should service

and repair fireplace.

15. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

16. To prevent performance problems with pro-

pane/LP units, do not use propane/LP fuel

tanks of less than 100 lb. capacity.

17. Provide adequate clearances around air

openings.

Advertising