PRESSURE TESTING FIREPLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 27,

page 19).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Place manual ignition switch in the OFF

position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 28 or 29). Apply

noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak.

5. Correct all leaks at once.

6. Light fireplace (see Operating Fireplace, page

25). Check all other internal joints for leaks.

7. Turn off fireplace (see To Turn Off Gas to

Appliance, page 27).

INSTALLATION

Continued

Figure 28 - Checking Gas Joints for

Natural Gas Fireplace

Figure 29 - Checking Gas Joints for

Propane/LP Gas Fireplace

Equipment Shutoff Valve

Manual Gas Valve

Gas Meter

Equipment Shutoff Valve

Manual Gas Valve

Propane/LP
Supply Tank

CONVENTIONAL FIREPLACE
INSTALLATION

Conventional installation of fireplace involves in-

stalling fireplace along with corner, face or cabinet

mantel with hearth base accessories against a wall

in your home.
Note:

Refer to instructions provided with the man-

tel for assembly instructions. Refer to the follow-

ing instructions for system installation. Refer to

instructions on page 23 for hood assembly. Blower

accessory should be installed prior to mantel if it is

being used (see Installing Variable Speed Blower

Accessory, page 13, or Installing Thermostatic

Blower Accessory, page 15).

1. Assemble cabinet mantel as shown in acces-

sory instruction sheet.

2. If blower is installed, install a properly

grounded, 120 volt three-prong electrical out-

let at fireplace location if an outlet is not there.

If possible, locate outlet so cabinet mantel will

cover it when installed (see Figure 30).

3. Place hearth base against wall at installation

location. Cut an access hole in hearth base to

run gas line to fireplace (see Figure 30). Make

sure to locate access hole so cabinet mantel will

cover it when installed. Note: You can secure

base to floor using wood screws. Countersink

screw heads and putty over.

4. Route flexible gas line through access hole in

hearth base.

5. Center cabinet mantel on hearth base (see Figure

31, page 21). Make sure mantel is flush against

wall and centered left to right on base.

6. Use screws provided with mantel accessory

to attach mantel assembly to base (see mantel

instruction sheet).

7. Attach flexible gas line to fireplace gas regula-

tor. See Connecting Fireplace to Gas Supply,

page 18.

Figure 30 - Placing Hearth Base

Accessory Against Wall

Electrical
Outlet

Hearth
Base

Rigid Pipe
and Gas
Shutoff Valve

Gas
Line
Access
Hole