9

WARNING: This appliance is

only for use with the type of gas

indicated on the rating plate. This

appliance is not convertible for

use with other gases.

WARNING: This appliance

is equipped for natural or pro-

pane/LP gas. Field conversion

is not permitted.

ELECTRICAL HOOKUP

This fireplace normally operates under 120

VAC/60 Hz line voltage. The electrical cord sup-

plied with your fireplace is five feet in length. You

must locate fireplace within reach of a 120 volt

grounded electrical outlet. If not, you must install

an electrical outlet within reach of the fireplace

power cord. The GA3555 outlet accessory may

be used for built-in applications.

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

INSTALLATION

Continued

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

0"

16"

0"

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 5.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace cabinet (see Figure 5).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42".

Figure 5 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

*

Example

INSTALLATION SEQUENCE

After unpacking fireplace (see Unpacking, page 4),

we suggest that you install your fireplace system

in the following sequence:

1. Removal of fireplace floor assembly (required)

2. Electrical connections for power cord (re-

quired)

3. Relocating wall switch (optional)

4. Installing blower accessory (optional)

5. Connecting fireplace to gas supply (required)

6. Checking gas connections (required)

7. Firebox installation, conventional or built-in

(required)

8. Installing brass perimeter trim (optional)

9. Installing fireplace hood (required)

10. Installing logs (required)

11. Installing fireplace screen (required)

Use the following instructions to complete

each step.

REMOVING FIREPLACE SCREEN
AND FLOOR ASSEMBLY

NOTICE: Shutoff gas supply

and disconnect heater from gas

supply if installing blower into

previously installed fireplace.

Contact a qualified service per-

son to do this.

1. Remove fireplace screen. Remove two screws

that hold fireplace screen in place for shipping.

These screws are located near top of screen.

Discard screws. Lift fireplace screen up and

pull out to remove.

2. If logs are installed, carefully remove the logs

and set aside, noting the properly mounted

location of each.