<COMMAND AGV>
Get/Set Auto Gain Control
Controller → Radio

AGV[\r]

AGV,[RSV],[RSV],[A_RES],[A_REF],[A_GAIN],[D_RES],[A_GAIN] [\r]

Radio → Controller
AGV,[RSV],[RSV],[A_RES],[A_REF],[A_GAIN],[D_RES],[A_GAIN] [\r]
AGV,OK[\r]

[A_RES]

: Analog Response Time (-4 - +6)

[A_REF]

: Analog Reference Gain (-5 - +5)

[A_GAIN]

: Analog Gain Range

( 0 - 15)

[D_RES]

: Digital Response Time (-8 - +8)

[D_GAIN]

: Digital Reference Gain(-5 - +5)

[RSV]

: Reserve Parameter

* This is always only “,”.


Get/Set AGC Setting.
This command is only acceptable in Programming Mode.

<COMMAND SCT>
Get System Count
Controller → Radio
SCT[\r]
Radio → Controller
SCT,###[\r]

: ### (0 - 500)


Returns the number of stored System.
This command is only acceptable in Programming Mode.

<COMMAND SIH>
Get System Index Head
Controller → Radio
SIH[\r]
Radio → Controller
SIH,[SYS_INDEX][\r]

Returns the first index of stored system list.
This command is only acceptable in Programming Mode.

<COMMAND SIT>
Get System Index Tail
Controller → Radio
SIT[\r]
Radio → Controller
SIT,[SYS_INDEX][\r]

Returns the last index of stored system list.
This command is only acceptable in Programming Mode.